Standard glazing units for Skylights

Standard glazing units for Skylights

Glazing Unit G3 - Solar Factor

Glazing Unit G3 - Solar Factor

  • Single chamber "Solar Factor" glazing unit  4HT – Tg16Ar – 4H
  • Sunscreen external pane toughened, 0.16" thick
  • Internal pane toughened, 0.16" thick
  • Warm TGI spacer
  • R-value 5.7 (glass)
  • Glazing cavity filled with inert gas – Argon
  • Models applicable to: FX, FV, FVE

Glazing Unit G31 - Solar Factor, laminated

Glazing Unit G31 - Solar Factor, laminated

  • Single chamber "Solar Factor" glazing unit 4HT– Tg14Ar – 33.2
  • Sunscreen external pane toughened, 0.16" thick
  • Internal pane laminated 33.2 PVB (0.25") – P2A class as per EN 356, 1(B)1 as per EN 12600
  • Warm TGI spacer
  • R-value 5.2 (glass)
  • Glazing cavity filled with inert gas – Argon
  • Models applicable to: FX, FV, FVE

Glazing unit G32 – Solar Factor

Glazing unit G32 – Solar Factor

  • Single chamber ”Solar Factor” glazing unit, 4HT – Tg16Ar – 4H, blackening at the edge of the glazing unit (1.2") colour RAL 9005
  • Sunscreen external pane toughened, 0.16" thick
  • Internal pane toughened, 0.16" thick
  • Warm TGI spacer
  • R-value 5.7 (glass)
  • Glazing cavity filled with inert gas – Argon
  • Model applicable to: FXC

Glazing unit G33 – Solar Factor, laminated

Glazing unit G33 – Solar Factor, laminated

  • Single chamber "Solar Factor" glazing unit, 4HT– Tg14Ar – 33.2, blackening at the edge of the glazing unit (1.2") colour RAL 9005
  • Sunscreen external pane toughened, 0.16" thick
  • Internal pane laminated 33.2 PVB (0.25") – P2A class as per EN 356, 1(B)1 as per EN 12600
  • Warm TGI spacer
  • R-value 5.2 (glass)
  • Glazing cavity filled with inert gas – Argon
  • Model applicable to: FXC

Glazing unit DU6 – Highly energy-efficient

Glazing unit DU6 – Highly energy-efficient

  • Double-chamber insulated glazing unit wider on 4 sides, 6H-18-4HT-18-44.2T
  • External pane reflective (#2) toughened, 0.024" thick
  • Middle pane toughened, 0.16" thick
  • Internal pane laminated 44.2 PVB (0.35") - P2A class as per EN 356, 1(B)1 as per EN12600
  • Warm TGI spacer
  • R-value 11.4 (glass) as per EN 673
  • Glazing cavity filled with inert gas – Argon
  • Models applicable to: DRF, DEF

* low emission coating (marked in red in the picture)

Standard glazing units for Pivot Roof Windows

Glazing unit – U3* – energy-efficient
Glazing unit – U3* – energy-efficient
  • Single chamber 4H – Tg16Ar – 4T.
  • External pane toughened, warm spacer, inner glass with low emission coating. Space between panes filled with inert gas- argon.

 

Glazing Unit – U6* – highly energy efficient
Glazing Unit – U6* – highly energy efficient
  • Double chamber glazing 6HT – Tg18Ar – 4H – Tg18Ar – 33.2T.
  • Consists of three panes: external toughened pane, internal toughened with low emission layer and inner ( concists of twopanes with 0.76mm (2x0.38mm) layer of PVB plastic membrane between them) laminated anti-burglary class P2A.
  • The unit has two warm TGI spacers.
  • The chamber cavities are filled with inert gas-argon.

 

Glazing Unit U8* - passive
Glazing Unit U8* - passive
  • Triple chamber glazing 4H – Tg12Kr – 4HT– Tg12Kr – 4HT – Tg12Kr – 4HT, consists of four toughened panes.
  • It has three low emission layers and warm TGI spacers. inner laminated anti-burglary class P2A. The unit has three warm TGI spacers.
  • The 12mm chamber cavities between the panes are filled with inert gaskrypton.

 

Glazing unit – P2* – Anti-burglary
Glazing unit – P2* – Anti-burglary
  • Single chamber glazing 4HS – Tg14Ar – 33.2T, laminated and anti-burglary class P2A according to standard EN 356.
  • Offers increased resistance against breakage.
  • The unit consists of external toughened pane with easy maintenance layer, warm TGI spacer and inner pane which has two 3mm thick sheets of glass with 0.76mm (2x0.38mm) layer of PVB plastic membrane between them.
  • The glazing cavity is filled with inert gas- argon.
  • On the inner side of the laminated glass it has a low emission coating which reduces penetration of UV rays by up to 99%.

 

Glazing unit – P5* – Anti-burglary and highly energy efficient

Glazing unit – P5* – Anti-burglary and highly energy efficient

  • Double chamber glazing 4HS  – 10 – 4HT – 8 – 33.2T, laminated and anti-burglary class P2A according to standard EN 356.
  • Offers increased resistance against breakage.
  • The glazing cavity is filled with inert gas- krypton.
  • Warm TGI spacer.
  • On the inner side of the laminated glass it has a low emission coating which reduces penetration of UV rays by up to 99%.

 

Glazing unit – R1 – acoustic

Glazing unit – R1 – acoustic

  • Single chamber glazing 6H–12–33.2SRT, laminated and anti-burglary class P2A according to PN-EN 356, offers increased resistance against breakage.
  • Warm TGI spacer.
  • The glazing unit consists of external toughened pane and inner laminated pane which has two 3mm thick sheets of glass with 0.76mm (2x0.38mm) layer of PVB plastic membrane between them. Additionally, it contains a sound-insulating membrane.
  • The glazing cavity is filled with inert gas- krypton.
  • On the inner side of the laminated glass it has a low emission coating.

 

Glazing unit – R3 – acoustic

Glazing unit – R3 – acoustic

  • Double chamber glazing 6H–16–4HT–18–33.2SRT, laminated and anti-burglary class P2A according to PN-EN 356, offers increased resistance against breakage
  • The glazing unit consists of external toughened pane, warm TGI spacer and inner toughened pane with a low emission coating. The inner laminated glass has two 3mm thick sheets of glass with 0.76mm (2x0.38mm) layer of PVB plastic membrane between them. Additionally, it contains a sound-insulating membrane.
  • The glazing cavity is filled with inert gas- argon. 
  • On the inner side of the laminated glass it has a low emission coating.

* low emission coating (marked in red in the picture)